5.3 Current input
This function group offers two independent application solutions, provided that the current
output of an external measured quantity, e.g. flow meter, is connected to the 4 20 mA input
of Liquisys M CPM 223 / 253. The following assignments then apply:
5.3.1 Monitoring the flow rate in the main stream
This arrangement is highly practical when the sample stream flowing through the flow assembly
(e.g. CPA 250) is totally independent of the flow rate in the main stream. This permits the
signalling of an alarm state in the main stream (flow rate too low or totally stopped) and trigger a
dosing switch-off, even if the measuring water stream is retained due to the installation
configuration.
Flow in
main stream
Flow alarm
Flow below
switch-off limit Z4
or flow failure
Flow
restored
Alarm relay
Relay contacts
of PID controller
ON
OFF
OFF
OFF
ON
ON
see field Z2 see field Z3
Fig. 5.4
Alarm signalling and
dosing switch-off by the
main stream
Flow in
main stream
Current signal
in mA
Current input
signal in %
Lower range limit
current input
Lower setting value
flow meter
40
Upper range limit
current input
Upper setting value
flow meter
20 100
PM253E5A.CHP
Liquisys M CPM 223 / 253 Instrument configuration
Endress+Hauser 27